Max10: ADC not working having .pof file

apps for adults

Max10: ADC not working having .pof file

Max10: ADC not working having .pof file

Sorry, you ought to be certain that to accomplish this. Delight click the verification hook on your own email. You are able to lso are-post during your character.

  • Intel Area
  • Product Assistance Community forums
  • FPGA
  • Programmable Gadgets
  • Max10: ADC not working which have .pof document

I’m currently coping with Max10M16DAF256 and i also have a problem with the fresh new ADC. While using the .sof document it functions great. While using the .pof document the fresh new ADC can not work any longer, i.e ADC info is usually no, just like the other people portion functions precisely.

So somehow the newest ADC situation relates to the power have series and also the ramp time of fuel supplies, however, a definite reason because of it problem has been not found yet ,

russian mail order bride documentary

I’ve plus seen whenever programming with .pof file and still allow the suppy current into the, the fresh ADC work. But immediately after reset the supply voltage (turn fully off as well as on once more), it generally does not work any more.

In case the second then you will want to ensure see the method that you release the fresh new ADC Ip from reset. Wait for the reset ‘a absolutely nothing longer’ after the power up. Disappointed this might voice a small unclear. This appears to be an everyday procedure on message board one to doesn’t seem to have gotten a definite, reliable service.

Should this be your board then you will want to test these and ensure the brand new rails rise monotonically. There are no sequencing standards but if the dont increase correctly – not conference this new Tramp date – the device often misbehave. Refer to ‘Figure step 3. Tracked Energy Supplies Ramp Up’ on the ‘ fuel management representative guide (

In addition discover a similar trouble with Max10 ADC in another thread, but like you told you there’s no services for it.

The fresh board was the care about framework board. The problem is a large number of our very own boards are working great having ” .pof “-document, and lots of of them understand this ADC state. To the chatrooms that have ADC condition, we investigated regarding gear of those chatrooms but unfortunately we missed any issue towards the hardware. Such as for example listed above, the fresh new forums will work which have ” .sof ” and also ” .pof “-file if have current is definitely to your.

This will make myself trust much more this problem may be electricity related. I suspect you really have you to (or higher) a bit slow or below ranked provides. You may be obviously on edge of long lasting issue is offered you have got doing work chatrooms.

Could you take a low working board, disconnect the power offers and you will strength it off counter supplies? My personal concern is you to definitely a not as much as rated railway actually as much as giving the inrush expected and you will dips resulting in the POR circuitry an excellent situation, which (perhaps) actually recorded.

You will be right. I did specific research from the fuel provides to possess Max10, and it looks like our very own analog also have takes a bit much time up to it is located at full voltage level (we are playing with Max10 twin also have unit, hence needs a couple of electronic provides and you can 1 analogue have).

As in Max10 Fuel administration associate book, it looks like only the history electric battery getting Max10 number (attached picture), so we made an effort to swtich on the analog have very first and you can wait a little for they to-arrive max height, immediately after which turn on additional two digital offers, which just take merely couples hundred or so s to-arrive maximum level. This helps the latest perhaps not-performing ADC to be performing sporatically (not at all times functioning).

Nevertheless when we grab a functional board (ADC usually work) and you may perform the contrary succession (i.e let one or two digital supplies on basic, then your analogue also provide), the fresh ADC is still operating (we expected which ought not to performs any longer).

After the have voltage is reset, the new ADC do no further performs once the people remains operating correctly

Leave us a comment